PLC xBusSync configuration
Collects PLC characterizations specific of the xBusSync PLC task functionality. It exists for all types of targets.xBusSync task configuration -Enable and bus I/O choice for the PLC xBusSync task executionDefault: 0Range: 0 – 30 – NoneUsage: task xBusSync is not executed1 – GDNet busUsage: task xBusSync is cyclically executed synchronous to the GDNet bus management2 – Local busUsage: task xBusSync is cyclically executed synchronous to the local bus management3 – Ethercat busUsage: task xBusSync is cyclically executed synchronous to the Ethercat bus managementxBusSync task executed every X ccyle -If the xBusSync configuration is not equal to None, set the number of cycles of the selected bus I/O management to wait before every xBusSync task execution.Default: 0Range: 0 – 50NB : setting 0 works as 1 cycleDirect I/O updating for GDNet bus -Enable the “direct” I/O management of the GDNet bus..Default: 0Range: 0 – 10 : mandatory for xBusSync configured None1 : mandatory for xBusSync configured GDNet bus, optionally for other busDirect I/O updating for local bus -Enable the “direct” I/O management of the local bus.Default: 0Range: 0 – 10 : mandatory for xBusSync configured None1 : mandatory for xBusSync configured local bus, optionally for other busDirect I/O updating for Ethercat bus -Enable the “direct” I/O management of the Ethercat bus.Default: 0Range: 0 – 10 : mandatory for xBusSync configured None1 : mandatory for xBusSync configured local bus, optionally for other bus